When a well analysis comes back with a high electrical conductivity, stained drippers, or a bicarbonate figure that makes the fertiliser recipe hard to manage, reverse osmosis (RO) is often the first treatment people mention. "Sometimes it is the right tool; sometimes it is more demanding than the…
全文
HortiDailyWhen a well analysis comes back with a high electrical conductivity, stained drippers, or a bicarbonate figure that makes the fertiliser recipe hard to manage, reverse osmosis (RO) is often the first treatment people mention. "Sometimes it is the right tool; sometimes it is more demanding than the problem requires," sees Victor Zhang with GlobalUF. He says the first step should not be to size a membrane plant. "It is to read the laboratory report against the crop, the irrigation method, and whether the system is open or recirculating."
© GlobalUF
Start with a complete irrigation-water analysisVictor joined GlobalUF as a sales manager in January 2026 and has worked in the water treatment industry since 2009. GlobalUF was founded in 2005. The Guangzhou-based company manufactures ultrafiltration, reverse osmosis, and containerized water-treatment systems. Victor's work focuses on membrane treatment for groundwater, brackish water, and seawater. With this background, he advises asking the laboratory for an irrigation suitability analysis, including EC, pH, alkalinity as CaCO3, bicarbonate, sodium, chloride, calcium, magnesium, hardness, iron, manganese, boron, sulphate and SAR. "Well water often changes with the season and with the pumping rate. Greenhouse guidance from the Government of Saskatchewan recommends a complete analysis at least four times a year."
How to read the ions that decide the treatmentThe figures below come from figures from commonly used greenhouse and ornamental irrigation guidelines published by the Government of Saskatchewan, Penn State Extension and Rutgers Cooperative Extension (fact sheet FS893). Plugs and recirculating systems generally need the tighter end of the range.
Sodium and chloride are not removed by ordinary filtration or acid injection, so they most often justify a membrane. Saskatchewan recommends sodium at 0–30 mg/L and indicates treatment above 50 mg/L (below 40 mg/L for plugs); Penn State Extension flags the same 50 mg/L threshold for sensitive or recirculating systems. For chloride, Saskatchewan recommends 0–50 mg/L and indicates treatment above 140 mg/L. Penn State Extension notes that most plants tolerate about 100 mg/L, though a few sensitive species may react at around 30 mg/L.
Bicarbonate and alkalinity buffer pH and can leave deposits, but acid injection is often enough. Saskatchewan recommends bicarbonate at 30–50 mg/L, with treatment indicated above 150 mg/L, and alkalinity of 1–100 mg/L as CaCO3 as a recommended range. Penn State Extension describes total alkalinity of about 30–100 mg/L as ideal. Hardness is a nutrient as well as a scaling risk: Penn State Extension considers 100–150 mg/L ideal, with scaling more likely above 150 mg/L. A domestic sodium-chloride softener is a poor irrigation fix because it exchanges hardness for sodium.
Iron is easily misread. Penn State Extension advises keeping iron below 0.3 mg/L in micro-irrigation to prevent clogging, with foliar spotting above 1.0 mg/L; Saskatchewan warns that emitters can block above 0.25 mg/L. This is first a pretreatment problem, not automatically an RO problem.
"EC is the summary, not the diagnosis," Victor says, referring to Saskatchewan, which gives an optimum of 0.3–1.0 mS/cm (dS/m) and does not recommend water above 2.2 mS/cm for bedding plants. Penn State Extension suggests keeping raw water, before fertiliser is added, below 1 mS/cm for plugs and below 1.5 mS/cm otherwise. "Two wells with the same EC can need different treatment if the dominant salts differ."
© GlobalUF
A skid-mounted reverse osmosis unit of the type used to treat irrigation or process water, photographed at the manufacturer's workshop in Guangzhou.
When blending permeate with raw water is enoughReverse Osmosis produces a low-salt permeate. "It does not follow that every litre of irrigation water must pass through the membrane. Saskatchewan notes that mixing treated and untreated water is sometimes necessary, and Penn State Extension lists dilution with rainwater as a standard option," says Victor.
"Blending permeate with raw well water, or with stored rainwater, can bring sodium, chloride and EC into the target range without sizing the plant for full peak flow. It retains some calcium and magnesium for the nutrient recipe and reduces the volume of concentrate. Blending is usually enough when the raw water is only moderately above the guideline range. It is usually not enough when sodium or chloride is far above the range for a recirculating or salt-sensitive crop, when the blend remains too salty once fertiliser is added, or when plugs need a low, stable starting EC. In those cases a larger share of RO water, or full RO, is the honest design."
© GlobalUF A skid-mounted media filter and reverse-osmosis train, photographed at the manufacturer's workshop in Guangzhou. Pretreatment such as media filtration is often required before RO when the source is well water.
If you do install RO on well water, keep it reliableA greenhouse RO plant on a borehole fails more often from what arrives in front of the membrane and from how it is run in the quiet season than from the membrane itself, Victor sees.
"Pretreatment for iron and turbidity comes first. Dissolved ferrous iron oxidises on contact with air or an oxidant and then deposits on pipes, drippers, and membranes. Oxidise and then filter, with a media filter and, where the load is fine or variable, ultrafiltration, finishing with a cartridge filter. Raw well water is rarely clean enough to feed RO directly."
Antiscalant is the second protection. "Concentrate is a richer version of the feed, and calcium carbonate, calcium sulphate, or silica can scale the membrane if recovery is pushed too hard or the dose is wrong. Choose antiscalant, and acid if needed, from the water analysis; there is no single recovery figure that is safe for every borehole."
He adds seasonal operating hours need a plan. "Irrigation demand rises and falls with radiation, crop stage, and season. Run the plant in sensible blocks into a permeate tank rather than starting and stopping many times a day or leaving membranes standing for weeks in stagnant water. Use a flush or preservation procedure in a quiet period."
And then, concentrate must be planned. "RO does not destroy salts; it produces a smaller, saltier concentrate stream that may also carry rejected iron, hardness and antiscalant. That stream has to be discharged or reused according to local rules, never as an informal overflow into a drain, a neighbour's land or the greenhouse recycling tank."
A short decision orderRead the irrigation analysis first, ion by ion. Treat alkalinity and iron with acidification, oxidation and filtration before assuming that every problem is an RO problem. Where sodium, chloride or EC is the constraint, ask whether a blend of permeate and raw water, or rainwater, will meet the target. If RO is justified, specify pretreatment, seasonal operation, and concentrate handling at the same time as the membranes. That sequence makes the technology the right size for the greenhouse that will have to live with it.